ADVANTAGES
APPROVED SUBSTRATES
Dry, completely cured concrete (at least 14 days old with HVAC operating)
FLOOR PREPARATION
Subfloor should be clean and dry
INSTALLATION
Quick and easy installation* – requires no additional seaming tape, cuts with a knife
PACKAGING
Available in 3' x 33.34' (100 sq. ft.) rolls and 6' x 75' (450 sq. ft.) contractor size rolls
TECHNICAL DATA
100% Synthetic SBR Rubber foam underlayment blended with post-consumer recycled granulated rubber tires, includes attached moisture film
Thickness — .085"
Density — 16 LBS
Weight — 2.24 oz/sq.ft.
Moisture Barrier — with lip and tape sealing system
Antimicrobial Treatment — ULTRA-FRESH®
Thermal Resistance — R-Value .20
Compression Resistance @ 25% — 8.6 psi
Compression Set @ 25% — 10.3%
Flammability Rating — Passes Federal Flammability Standards DOC-FF-1-70
Smoke Density — Passes, 85 max
Product Emissions — Exceeds VOC emissions requirements, environmentally friendly
SOUND ABSORPTION PROPERTIES
Impact Insulation Class (IIC) This method is to measure the impact sound transmission performance of a floor-ceiling assembly (sound transmission through the floor)
IIC Flooring Sub-Floor
70 Laminate/Engineered 6" concrete with ceiling assembly
59 Hardwood 6" concrete with ceiling assembly
Sound Transmission Class (STC) This method is to measure the air-borne sound insulating property of a partition element for effectiveness in blocking sound
STC Flooring Sub-Floor
71 Laminate/Engineered 6" concrete with ceiling assembly
53 Hardwood 6" concrete with ceiling assembly
LEED Credits
MR 4.1 – 10% recycled content
MR 4.2 – 20% recycled content
MR 5.1 – 10% content manufactured within 500 miles of project
MR 5.2 – 20% content manufactured within 500 miles of project
EQ 4.3 – low emitting VOC's
- Eco-Silencer+™ is made with 100% post-consumer recycled granulated rubber tires.
- The moisture barrier film and tape strip combine to lock out moisture and allow for quick and easy installation.
- Suitable for floating laminate, engineered and hardwood flooring
- Contains Ultra-Fresh®, an antimicrobial protection that resists mold and mildew
- Crushpruf™ technology resists indentation that enables your floors to perform to its fullest potential and last a lifetime
- Provides cushioned comfort under hard laminate flooring
- Eliminates minor subfloor imperfections
- Offers the industry's best limited lifetime warranty
- Suitable for radiant heat flooring systems
- Install Eco-Silencer+™ with film down against concrete/subfloor
APPROVED SUBSTRATES
Dry, completely cured concrete (at least 14 days old with HVAC operating)
- 3/4" interior plywood or OSB flooring
- Waterproofing and crack-isolation membranes
- Cement backer units
FLOOR PREPARATION
Subfloor should be clean and dry
- In geographic areas where concrete subfloors are subject to excessive moisture, a calcium chloride moisture test is required. Vapor emission readings in excess of 4 lbs. per 1,000 square feet in 24 hrs will require additional protection such as concrete sealant or polyethylene sheeting.
INSTALLATION
Quick and easy installation* – requires no additional seaming tape, cuts with a knife
- Install Eco-Silencer+™ with film DOWN on subfloor
- Roll out underlayment with tape strip next to wall. Roll out next row in same manner butting underlayment close to first row (do not overlap) and covering the moisture barrier film. Remove the tape strip and secure the overlapping moisture barrier film.
- Install flooring according to the manufacturer's installation instructions
PACKAGING
Available in 3' x 33.34' (100 sq. ft.) rolls and 6' x 75' (450 sq. ft.) contractor size rolls
TECHNICAL DATA
100% Synthetic SBR Rubber foam underlayment blended with post-consumer recycled granulated rubber tires, includes attached moisture film
Thickness — .085"
Density — 16 LBS
Weight — 2.24 oz/sq.ft.
Moisture Barrier — with lip and tape sealing system
Antimicrobial Treatment — ULTRA-FRESH®
Thermal Resistance — R-Value .20
Compression Resistance @ 25% — 8.6 psi
Compression Set @ 25% — 10.3%
Flammability Rating — Passes Federal Flammability Standards DOC-FF-1-70
Smoke Density — Passes, 85 max
Product Emissions — Exceeds VOC emissions requirements, environmentally friendly
SOUND ABSORPTION PROPERTIES
Impact Insulation Class (IIC) This method is to measure the impact sound transmission performance of a floor-ceiling assembly (sound transmission through the floor)
IIC Flooring Sub-Floor
70 Laminate/Engineered 6" concrete with ceiling assembly
59 Hardwood 6" concrete with ceiling assembly
Sound Transmission Class (STC) This method is to measure the air-borne sound insulating property of a partition element for effectiveness in blocking sound
STC Flooring Sub-Floor
71 Laminate/Engineered 6" concrete with ceiling assembly
53 Hardwood 6" concrete with ceiling assembly
LEED Credits
MR 4.1 – 10% recycled content
MR 4.2 – 20% recycled content
MR 5.1 – 10% content manufactured within 500 miles of project
MR 5.2 – 20% content manufactured within 500 miles of project
EQ 4.3 – low emitting VOC's